Verification of bell protection elements’ tightness
Product description
Requirements
- After applying the seal, the bell protection elements must be checked for tightness;
- Checking the under-pressure;
- Leak rate 2 cm³/min
- 40 sec. cadence duration/sample piece;
- »OK« marking after verification
- Option for other variants;
- Compact and mobile execution;
- Manual operation.
Solution
- The testing device consists of a transportable frame;
- The vacuum pump and the leak testing device are integrated into the frame;
- The support for the processed pieces, quickly interchangeable, with integrated entrance test;
- The component is tightened using Destaco tightening devices;
- JW Fröhlich leak testing device with manual control;
- »OK« pneumatic marking with the lathe spike
- Possibility of calibration using the main sample piece;