Product description
Requirements
- After applying the fitting, the case sealing must be tested;
- 3 sample versions with short modification time;
- Checking the overpressure and underpressure
- Cycle duration: 30 sec. per sample
- Labelling the tested samples with I.O result
- Confirmation of NIO component by the operating staff
- Automatic and manual operation
Solution
- Two separated testing cells, fully automated, with double drawer mechanism;
- Components support for all sample versions;
- Only one testing program for all sample versions;
- Bodies with volume modification, with quick change, to maintain the check volume at the same value for each sample version;
- 2 JW-Fröhlich machines for testing leaks, with Profibus interface;
- 2 channels security equipment, with protection door monitoring and lock
- The NIO components shall be evacuated by manual confirmation, by using a chamfer for NIO monitored with sensors;
- Calibration possibility by Master sample;
- Siemens touch panel and PLC control with Profibus interface;
- Programming the machine through Siemens S7;